Anthony Liftgates don't break often, but even the most rugged parts don't last forever. Damage or normal wear and tear can interfere with normal liftgate operation. We've prepared this section to help guide you step-by-step through the most common troubleshooting procedures for liftgate repair. Simply locate and click the description that most closely matches your issue, then follow the troubleshooting steps outlined on that page.

<< Return to Troubleshooting Guide

Hydraulic oil leaks from cylinder rod end.  

Possible Cause #1 Gland nut on end of cylinder loose.
Action -

Tighten gland nut snugly only. Usually 1/4 to 1/2 is usually enough. DO NOT over-tighten.

(Diagnosis time - 0 / Repair time - 15 minutes).

Part Numbers - N/A
Possible Cause #2 Cylinder rod pitted due to excessive wear or object dropping on rod.
Action -

Replace cylinder.

(Diagnosis time - 10 minutes / Repair time - 1/2 hr.).

Part Numbers - ATU-25100 (AST-1500, AST-2000, ASTL-1800, ATU-1800)
ATU-50100 (ASTL-2500, AST-2500, ATU-2500 Cylinder)
ATU-75100 (AST-3000, ATU-300, ATU-3500 Cylinder)
ATU-25113-WR (ATU-25100 Seal kit)
ATU-50123-WR (ATU-50100 Seal kit)
ATU-75112 (ATU-75100 Seal kit)