Platform will not open.
Possible Cause #1 |
Blown circuit breaker. |
Action - |
Check all connectors and connections for worn or loose parts, replace any worn terminals with 'heat shrink' factory terminals. (Reset circuit breaker).
(Diagnosis time - 0 - / Repair time 0) |
Part Numbers - |
A-150495 - Circuit breaker |
Possible Cause #2 |
Inline fuse blown. |
Action - |
Replace blown fuse with ATO or ATC fuse (10 Amp)
(Diagnosis time - 0 / Repair time - 0 ). |
Part Numbers - |
N/A |
Possible Cause #3 |
Bad opening valve coil. |
Action - |
Remove coil from cartridge and test magnetism of inside of coil with metal object (i.e. screwdriver) while energizing "down" control side of switch only.
(Diagnosis time - 15 minutes / Repair time - 30 minutes). |
Part Numbers - |
A-176306 - Opening valve coil |
Possible Cause #4 |
Clogged or bad opening valve on power unit. |
Action - |
Remove valve, clean and inspect. If plunger will not move freely, replace.
(Diagnosis time - 15 minutes / Repair time - 30 minutes). |
Part Numbers - |
A-176305 - Opening valve |