Platform will not close, motor does not run.
Possible Cause #1 |
Circuit breaker tripped. |
Action - |
Reset circuit breaker.
(Diagnosis time - 0 / Repair time - 0 ).
|
Part Numbers - |
A-150495 Circuit breaker |
Possible Cause #2 |
In line fuse blown |
Action - |
Replace fuse with ATO or ATC (10 Amp fuse)
(Diagnosis time - 0 / Repair time - 0 ).
|
Part Numbers - |
N/A |
Possible Cause #3 |
Defective start solenoid |
Action - |
Replace bad solenoid.
(Diagnosis time - 15 minutes / Repair time - 30 minutes).
|
Part Numbers - |
ATU-120 - Motor start solenoid |
Possible Cause #4 |
Corroded or loose wire connections. |
Action - |
Check all wire connections on power unit for corrosion or looseness. Replace defective terminals with 'heat shrink' factory type terminals. Check main power cable from batteries, to circuit breakers, to cut off switch, to power unit.
(Diagnosis time - 15 minutes / Repair time - 1/2 hr.).
|
Part Numbers - |
N/A |
Warranty Information: |
Base Warranty: |
3 Years on mechanical structure.
2 Years on hydraulic & electrical components.
|
Warranties are void if genuine Anthony parts are not used.
FOR ANTHONY LIFTGATES ASSISTANCE CALL (800) 482-0003
|