Platform will not close at all, motor does run.
Possible Cause #1 |
Bad cartridge valve coil. |
Action - |
Remove coil from cartridge and test magnetism of inside of soil with metal object (i.e. screwdriver) while energizing 'down' control side of switch only.
(Diagnosis time - 15 minutes / Repair time - 30 minutes).
|
Part Numbers - |
A-176306 - Coil |
Possible Cause #2 |
Closer valve stuck in the closed position. |
Action - |
With platform on the ground, remove closing valve, clean and inspect. If plunger not moving freely, replace valve.
(Diagnosis time - 15 minutes / Repair time - 30 minutes). |
Part Numbers - |
A-176304 - Closer valve |
Warranty Information: |
Base Warranty: |
3 Years on mechanical structure.
2 Years on hydraulic & electrical components.
|
Warranties are void if genuine Anthony parts are not used.
FOR ANTHONY LIFTGATES ASSISTANCE CALL (800) 482-0003
|