Anthony Liftgates don't break often, but even the most rugged parts don't last forever. Damage or normal wear and tear can interfere with normal liftgate operation. We've prepared this section to help guide you step-by-step through the most common troubleshooting procedures for liftgate repair. Simply locate and click the description that most closely matches your issue, then follow the troubleshooting steps outlined on that page.

<< Return to Troubleshooting Guide

Platform closes and/or opens too slow.  

Possible Cause #1 Improper adjustment of in-line flow control valve.
Action - Re-adjust in-line flow control valve (located inside pump box). If clogged, remove valve, clean and reinstall. (Replace if needed).
*Proper adjustment is 5 to 6 seconds either direction.

(Diagnosis time - 0 - / Repair time - 15 minutes).
Part Numbers - A-176560 - Adjustable flow valve
Warranty Information:
Base Warranty:

3 Years on mechanical structure.

2 Years on hydraulic & electrical components.