Platform lowers in a jerky fashion.
Possible Cause #1 |
Excessive dirt or grease on Aluminum Runner. |
Action - |
Pressure wash Aluminum Runner and columns to clean.
(Diagnosis time- 0 - / Repair time - 20 minutes).
|
Part Numbers - |
N/A |
Possible Cause #2 |
Air in hydraulic lines. |
Action - |
Fill reservoir to within 1/2' of full with platform on ground with Pennzoil Arctic hydraulic fluid. |
Part Numbers - |
N/A |
Possible Cause #3 |
Worn sprockets & or lift chain. |
Action - |
Inspect all sprockets and lift chain on railgate, replace if needed.
(Diagnosis time - 15-minutes/ Repair time - 15 minutes per sprocket).
|
Part Numbers - |
AR-18-38 (Sprocket - 13 tooth) AR-18-40 (Sprocket - 25 tooth) AR-18-39 (Sprocket - 19 tooth) |
Warranty Information: |
Base Warranty: |
3 Years on mechanical structure.
2 Years on hydraulic & electrical components.
|
Warranties are void if genuine Anthony parts are not used.
FOR ANTHONY LIFTGATES ASSISTANCE CALL (800) 482-0003
|