Platform lowers extremely slowly.
Possible Cause #1 |
Lowering valve not opening fully or is clogged with contaminates. |
Action - |
With platform on ground, remove valve. Inspect and clean valve with parts solvent, then blow out with air. Replace if needed. (Diagnosis time - 1/2 hr. / Repair time - 15 minutes). |
Part Numbers - |
ATU-121 (Monarch Lowering Valve) ATU-479 (Fenner Lowering Valve) |
Possible Cause #2 |
Defective pressure compensated flow control valve. |
Action - |
Try lowering platform without valve in place. Clean or replace if found to be contaminated. (Diagnosis time- 1/2 hr. / Repair time - 1/2 hour). |
Part Numbers - |
A-150035 (AST-1500, AST-2000, ASTL-1800, ATU-1800) A-150038 (ASTL-2500, AST-2500, ATU-2500) AR-18-72 (AST-3000, ATU-3000, ATU-3500) |
Possible Cause #3 |
Restricted or pinched hydraulic hose or breather hose. |
Action - |
Check all hydraulic hoses for loose connections or pinching. Replace hose if damaged. (Diagnosis time - 15 minutes / Repair time - 15 minutes). |
Part Numbers - |
ATU-129 (Hydraulic hose) ATU 125 ( Return hose) |
Possible Cause #4 |
Cylinder rod scored, or pitted. |
Action - |
Replace cylinder. (Diagnosis time - 10 minutes / Repair time 1/2 hr.). |
Part Numbers - |
ATU-25100 (AST-1500, ASTL-1800, AST-2000, ATU-1800) ATU-50100 (ASTL-2500, AST-2500, ATU-2500 CYLINDER) ATU-75100 (AST-3000, ATU-3000, ATU-3500 CYLINDER) ATU-25113-WR (ATU-25100 SEAL KIT) ATU-50123-WR (ATU-50100 SEAL KIT) ATU-75112 (ATU-75100 SEAL KIT) |